66 Part Number 000007661 6/12
Contactor Closed?
Line Voltage To
Compressor?
YES
YES
NO
YES
NO
Verify:
Compressor Overload is Closed
Start Components Function
Fan Cycling Control Functions
Condenser Fan Motor Functions
Water cooled only:
Water Regulating Valve Functions
Repair Wiring
Replace Contactor
Line Voltage To
Compressor Contactor
Coil?
NO
Repair Wiring
Replace Rotation Sensor/Time Delay Relay
No
Yes
Power To Contactor Coil?
Yes
Install
Compressor Time
Delay Jumper