Section 4 Maintenance
Part Number 000000966 10/09 4-5
Multiple Evaporator Ice Machines
A. Remove Splash Shields.
Grasp the top center of splash shields.
Lift up and then out.
B. Remove ice thickness probe.
Compress the hinge pin on the top of the ice
thickness probe.
Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be
cleaned at this point without complete removal. If
complete removal is desired, disconnect the ice
thickness control wiring from the control board.
C. Remove the water trough shield.
Grasp the water trough shield in the center and the
left end.
Flex the water trough shield in the center and pull the
left end forward until clear of the side wall. Repeat for
the right end.
Pull water trough shield forward to remove.
D. Remove the water trough.
Depress the two tabs on the top of the water trough.
Turn left and right ice dampers down to clear water
trough.
Pull forward on the water trough to remove.
NOTE: Proceed to page 4-6, Step 7.
A.
B.
C.
D.