Manitowoc I0320 Specifiche Pagina 158

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 157
158 Part Number STH025 2/14
Refer to Sequence of
Operation &
Wiring Diagrams
YES
YES
YES
NO
NO
NO
YES
NO
YES
Is harvest valve energized?
Is head pressure high &
suction pressure low
in harvest?
Replace Harvest Valve
Is head pressure low &
suction pressure low
in harvest?
Is head pressure normal &
suction pressure normal
in harvest?
Refer to Harvest Pressure
Regulating Valve
Diagnostics
Repeat this flowchart &
verify all data
Refer to Symptom #4 -
Will Not Harvest, Freeze
Cycle Normal & Ice Cubes are
Melted Flowchart
Single Evaporator Systems with Dual Harvest Valves: If one Harvest Vavle is open and the other is restricted / stuck closed you may have
normal harvest pressures. Look for ice not melting on one side of the evaporator.