Manitowoc S model Specifiche Pagina 229

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 228
Part Number 80-1230-9 10/10 229
Component Specifications
MAIN FUSE
The main fuse is 250 Volt, 10 amp.
ICE/OFF/CLEAN TOGGLE SWITCH
Single-pole, double-throw switch. The switch is
connected into a varying low D.C. voltage circuit.
FAN CYCLE CONTROL
(Self-Contained Air-Cooled Models Only)
HIGH PRESSURE CUTOUT (HPCO) CONTROL
TORQUE VALUES
Model Cut-In (Close) Cut-Out (Open)
QF800/QC700
250 ±5
(1723 kPa ±.34)
(17.23 bar ±.34)
200 ±5
(1517 kPa ±.34)
(15.17 bar ±.34)
Cut-Out Cut-In
450 psig ±10
(3103 kPa ±69)
31 bar ±.69
Automatic Reset
(Must be below 300 psig
(2068 kPa 20.68 bar) to reset.)
Location Inch Pounds Set Screws
M24 Coupling 5-20 #10-24
Evap to Foundation 60 +/- 5 #1/4-20
Use Loctite 242
Vedere la pagina 228