ICE THICKNESS CHECK
After a Harvest cycle, inspect the ice cubes in the ice
storage bin. The ice thickness probe is set to maintain
an ice bridge of 1/8 in. (3.2 mm). If an adjustment is
needed, follow the steps below.
1. Turn the ice thickness probe adjustment screw
clockwise for a thicker ice bridge, or
counterclockwise for a thinner ice bridge.
2. Make sure the ice thickness probe wire and bracket
do not restrict movement of the probe.
SV3113
ADJUSTING
SCREW
1/8 IN. ICE BRIDGE
THICKNESS
ICE THICKNESS ADJUSTMENT
1/8” ICE BRIDGE THICKNESS