–90–
*Low pressure Control (close on pressure increase).
**The fan motor is wired through a fan cycle pressure control, therefore, it may cycle on and off.
6. Harvest Off Off Off On On On Closed **On
Bin Switch
Activation
7. Auto Shut-Off Off Off Off Off Off Off Open Off
Until Bin
Switch
Recloses
Energized Parts Chart – Model QDUAL (Continued)
Ice Making
Sequence of
Operation
Control Board Relays Condensing Unit
Length
of Time
1
Water
Pump
2
Water
Fill
Solenoid
3
Dump
Valve
4
Liquid
Line
Solenoid
5
Cool
Vapor
Valve
1
6
Cool
Vapor
Valve
2
LPCO*
Contactor
Coil
Contactor
Fan Motor
and
Compressor